to series Pilkington Suncool®
to series Pilkington Suncool®

Pilkington
Suncool®-R Silver 50/27 Pro T

Architectural glass with a silvery tint, unusually low solar factor and high reflectivity

Thanks to the technology of magnetron coating, the glass transmits light, but does not color it. It will be perfect for decorating facades of buildings that require a high degree of illumination and reflection.

 The product must be hardened. Bending, lamination, ceramic and organic paints are possible.

Advantages

  • Color shade

    Color shade

    A pronounced hue that is only visible in reflected light from the façade

  • Selectivity

    Selectivity

    Ideal balance between light transmission and sun protection

  • Heat protection

    Heat protection

    Excellent thermal insulation properties (Ug coefficient > 1.0 W / m2K)
  • Saving

    Saving

    Helps reduce air conditioning and space heating costs

Indicators

LT
LRout
LRin
DET
ER
EA
SF
SC
Ug
Ug
% % % % % % % % W/m 2 К W/m 2 К
Light transmission, LT, % 47 Light reflectance out, LRout, % 31 Light reflectance inside, LRin, % 25 Direct energy transmittance, DET, % 27 Energy reflectance, ER, % 36 Energy absorptance, EA, % 37 Solar factor, SF, % 29 Shading coefficient, SC, % 0.33 Ug-value (air-filled), W/m 2 К 1.0 Ug-value (argon-filled), W/m 2 К 0.68
Characteristics calculated for formula 6 | - 16 Ar - 4 Optifloat in accordance with GOST EN 410-2014, GOST EN 673-2016 (R0 for Moscow conditions using the STIS thermal calculator software).
LT
LRout
LRin
DET
ER
EA
SF
SC
Ug
Ug
% % % % % % % % W/m 2 К W/m 2 К
Light transmission, LT, % 47 Light reflectance out, LRout, % 31 Light reflectance inside, LRin, % 25 Direct energy transmittance, DET, % 27 Energy reflectance, ER, % 36 Energy absorptance, EA, % 37 Solar factor, SF, % 29 Shading coefficient, SC, % 0.33 Ug-value (air-filled), W/m 2 К 1.3 Ug-value (argon-filled), W/m 2 К 1.0
All values are calculated for the central area of the IG unit 6| - 16 Ar - 4 according to EN 410 and EN 673 climatic conditions.
LT
LRout
LRin
DET
ER
EA
SHGC
SC
Ug
Ug
% % % % % % % % W/m 2 К W/m 2 К
Light transmission, LT, % 45 Light reflectance out, LRout, % 34 Light reflectance inside, LRin, % 26 Direct energy transmittance, DET, % 24 Energy reflectance, ER, % 39 Energy absorptance, EA, % 38 Solar heat gain coefficient, SHGC 28 Shading coefficient, SC 0.32 Ug-value (air-filled), W/m 2 К 1.27 Ug-value (argon-filled), W/m 2 К 1.38
All values are calculated of the IG unit 6| - 16 - 6 according to NFRC 100-2010 climatic conditions using a production database with Window 6.3.

Technical data

  • Formats: Jumbo (6000 x 3210 mm), LES (2550 x 3210 mm)
  • Thickness: 4, 6, 8, 10, 12
  • Use in an IG Unit: mandatory, coated inside
  • Must be hardened: certainly
  • Can be bent: possibly
  • Can be laminated: possibly
  • Decoration: application of ceramic and organic paints possible

Application area