to series Pilkington Suncool®
to series Pilkington Suncool®

Pilkington
Suncool® 70/35 Pro T

Suitable for glazing public and residential buildings where sun protection and load reduction on air conditioning systems

Architectural glass in a neutral shade with a reflectance close to that of ordinary float glass. 

A distinctive feature is the highest selectivity achieved due to the low solar factor and high light transmission.

The product must be hardened. Bending, lamination, ceramic and organic paints are possible.

For those cases where heat treatment of glass is not required, there is a non-tempering version of the product Pilkington Suncool 70/35.


Advantages

  • Selectivity

    Selectivity

    Ideal balance between light transmission and sun protection

  • Heat protection

    Heat protection

    Excellent thermal insulation properties (Ug coefficient > 1.0 W / m2K)
  • Saving

    Saving

    Helps reduce air conditioning and space heating costs

Indicators

LT
LRout
LRin
DET
ER
EA
SF
SC
Ug
Ug
% % % % % % % % W/m 2 К W/m 2 К
Light transmission, LT, % 70 Light reflectance out, LRout, % 16 Light reflectance inside, LRin, % 17 Direct energy transmittance, DET, % 35 Energy reflectance, ER, % 35 Energy absorptance, EA, % 30 Solar factor, SF, % 37 Shading coefficient, SC, % 0.43 Ug-value (air-filled), W/m 2 К 1.0 Ug-value (argon-filled), W/m 2 К 0.68
Characteristics calculated for formula 6 | - 16 Ar - 4 Optifloat in accordance with GOST EN 410-2014, GOST EN 673-2016 (R0 for Moscow conditions using the STIS thermal calculator software).
LT
LRout
LRin
DET
ER
EA
SF
SC
Ug
Ug
% % % % % % % % W/m 2 К W/m 2 К
Light transmission, LT, % 70 Light reflectance out, LRout, % 16 Light reflectance inside, LRin, % 17 Direct energy transmittance, DET, % 35 Energy reflectance, ER, % 35 Energy absorptance, EA, % 30 Solar factor, SF, % 37 Shading coefficient, SC, % 0.43 Ug-value (air-filled), W/m 2 К 1.3 Ug-value (argon-filled), W/m 2 К 1.0
All values are calculated for the central area of the IG unit 6| - 16 Ar - 4 according to EN 410 and EN 673 climatic conditions.
LT
LRout
LRin
DET
ER
EA
SHGC
SC
Ug
Ug
% % % % % % % % W/m 2 К W/m 2 К
Light transmission, LT, % 69 Light reflectance out, LRout, % 16 Light reflectance inside, LRin, % 17 Direct energy transmittance, DET, % 30 Energy reflectance, ER, % 38 Energy absorptance, EA, % 32 Solar heat gain coefficient, SHGC 37 Shading coefficient, SC 0.43 Ug-value (air-filled), W/m 2 К 1.34 Ug-value (argon-filled), W/m 2 К 1.38
All values are calculated of the IG unit 6| - 16 - 6 according to NFRC 100-2010 climatic conditions using a production database with Window 6.3.

Technical data

  • Formats: Jumbo (6000 x 3210 mm), LES (2550 x 3210 mm)
  • Thickness: 4, 6, 8, 10, 12
  • Use in an IG Unit: mandatory, coated inside
  • Must be hardened: must be
  • Can be bent: must be
  • Can be laminated: must be
  • Decoration: ceramic and organic paints can be used

Application area