to series Pilkington Suncool®
to series Pilkington Suncool®

Pilkington
Suncool® 70/35 Pro T

An architectural highly selective glass of neutral tint with a light reflection close to ordinary float glass

Suitable for facades of public and residential buildings where solar protection and savings on air condition are important.

This glass must be heat-treated (tempered or heat-strengthened). Bending and lamination are possible.

If heat-treatment of the glass is not required please use non-temperable version of this glass without Pro T index: Pilkington Suncool 70/35

Advantages

  • Neutral shade

    Neutral shade

    The most neutral shade in reflected light and in the lumen

  • High light transmission

    High light transmission

    Lets a lot of natural light into the room

  • Solar protection

    Solar protection

    Blocks solar heat and maintains indoor comfort in summer

  • Thermal protection

    Thermal protection

    Excellent thermal insulation characteristics
  • Saving

    Saving

    Significantly reduces air conditioning and heating costs

  • Wide range of processing options

    Wide range of processing options

    This coated glass can be heat-treated or laminated

Indicators

LT
LRout
LRin
DET
ER
EA
SF
SC
Ug
Ug
% % % % % % % % W/m 2 К W/m 2 К
Light transmission, LT, % 70 Light reflectance out, LRout, % 16 Light reflectance inside, LRin, % 17 Direct energy transmittance, DET, % 35 Energy reflectance, ER, % 35 Energy absorptance, EA, % 30 Solar factor, SF, % 37 Shading coefficient, SC, % 0.43 Ug-value (air-filled), W/m 2 К 1.0 Ug-value (argon-filled), W/m 2 К 0.68
Characteristics calculated for formula 6 | - 16 Ar - 4 Optifloat in accordance with GOST EN 410-2014, GOST EN 673-2016 (R0 for Moscow conditions using the STIS thermal calculator software).
LT
LRout
LRin
DET
ER
EA
SF
SC
Ug
Ug
% % % % % % % % W/m 2 К W/m 2 К
Light transmission, LT, % 70 Light reflectance out, LRout, % 16 Light reflectance inside, LRin, % 17 Direct energy transmittance, DET, % 35 Energy reflectance, ER, % 35 Energy absorptance, EA, % 30 Solar factor, SF, % 37 Shading coefficient, SC, % 0.43 Ug-value (air-filled), W/m 2 К 1.3 Ug-value (argon-filled), W/m 2 К 1.0
All values are calculated for the central area of the IG unit 6| - 16 Ar - 4 according to EN 410 and EN 673 climatic conditions.
LT
LRout
LRin
DET
ER
EA
SHGC
SC
Ug
Ug
% % % % % % % % W/m 2 К W/m 2 К
Light transmission, LT, % 69 Light reflectance out, LRout, % 16 Light reflectance inside, LRin, % 17 Direct energy transmittance, DET, % 30 Energy reflectance, ER, % 38 Energy absorptance, EA, % 32 Solar heat gain coefficient, SHGC 37 Shading coefficient, SC 0.43 Ug-value (air-filled), W/m 2 К 1.34 Ug-value (argon-filled), W/m 2 К 1.38
All values are calculated of the IG unit 6| - 16 - 6 according to NFRC 100-2010 climatic conditions using a production database with Window 6.3.

Technical data

  • Formats: Jumbo (6000 x 3210 mm), LES (2550 x 3210 mm)
  • Thickness: 4, 6, 8, 10, 12
  • Use in an IG Unit: mandatory, coated inside
  • Must be hardened: must be
  • Can be bent: must be
  • Can be laminated: must be
  • Decoration: ceramic and organic paints can be used

Application area